1786-Slot 0 Drive Array Recovery Needed The following SAS/SATA drive(s).The Smart Storage Administrator software shows the status "Ready for Rebuild" on our RAID5 Array. We have two arrays: A RAID1 with two disks (obviously) and a RAID5 with three disks. HP P410 Smart Array не запускает rebuild В ACU висит ворнинг (776 (Ready for recovery) Logical drive is queued for rebuilding). И дальше ничего не происходит.Добавлено через 12 минут кроме этого журнал показывает ошибку "1786-Slot X Drive Array Recovery Needed". o Press the F2 key to continue without recovery of data to… 1786-Slot 1 Drive Array Recovery Needed. Automatic Data Recovery Previously Aborted!... ...3. Replace drive X . (depending on the fault-tolerance level, all data may be lost if another drive fails). 1788-Slot X Drive Array Reports Incorrect Drive Replacement... ...
スイッチ Array コントローラのエラー内容
1786-slot 1 Drive Array Recovery Needed; 1787-drive-array Operating ... HP ProLight Server Manual Online: 1786-slot 1 Drive Array Recovery Needed, 1787-drive-array Operating In Interim Recovery Mode. Automatic Data Recovery ... raid - HP drive array "ready for rebuild" (RAID5) - Server Fault 1786-Slot 0 Drive Array Recovery Needed The following SAS/SATA drive(s) ... If it's on the RAID5 array, you probably have run into a URE situation ... can't be read from reliably to complete the reconstruction of the failed disk. 1785-slot X Drive Array Not Configured; 1786-slot 1 Drive Array ... controller. 1786-Disk 0 Software RAID Failure, Booting Disk 1. Audible Beeps: None ... 1786-Slot 1 Drive Array Recovery Needed... ...The following SCSI drive(s ) ...
raid - HP drive array "ready for rebuild" (RAID5) - Server Fault
HP Log on gitmirror.dmz.phx1.mozilla.com is WARNING: WARNING 0003: POST Error: ... POST Error: 1786-Drive Array Recovery Needed ... Smart Array P410i in Slot 0 ... HP DL 380 G5 Hard Drives Flashing Orange - Spiceworks 1786 - Slot 1 drive Array Recovery Needed. The following disk drives need automatic automatic data recovery (rebuild) 1716 - Slot 1 drive Array - Unregenerable Media Errors detected on drives during previous rebuild or auto reliability monitoring (ARM). Scan problem will be fixed automatically when the sectors are overwritten. 1716 Slot X Drive Array - tramvianapoli.com "1716-Slot 0 Drive Array 1716 slot x drive array - Unrecoverable Media Errors Detected on Drives during previous Rebuild or Background Surface appysis (ARM) ..Proliant ML350 E200i SmartArray Controller Fails T.. P3211 db2034 ilom log - Wikimedia
1786 - Slot 1 drive Array Recovery Needed. The following disk drives need automatic automatic data recovery (rebuild) 1716 - Slot 1 drive Array - Unregenerable Media Errors detected on drives during previous rebuild or auto reliability monitoring (ARM). Scan problem will be fixed automatically when the sectors are overwritten.
Solved: how to start array rebuild - Hewlett Packard ... After the end of the rebuild the status of the first array is "queued for rebuilding" how can i start the rebuild of the array, if i can. And when I reboot the server, it was display after initialize Smart Array Controller as: 1786-Slot 0 Drive Array Recovery Needed. The following disk drive(s) need Automatic Data Recovery (Rebuild): raid - HP drive array "ready for rebuild" (RAID5) - Server ...
Solved: how to start array rebuild - Hewlett Packard ...
Сбой RAID / Microsoft SQL Server / Sql.ru | Форум У вас 1-й сбой массива произошел 15 октября POST Error: 1787-Drive Array Operating in Interim Recovery Mode 15.10.2011 13:50. И с тех пор массив не восстановили, а он целую неделю работал в режиме восстановления. Вероятно не было исправного диска, поэтому так и работал.
DO's and DON'Ts for RAID-5 Troubleshooting Without Data ... The RAID-5 disk drive array is one of the most prevalent means of providing mass data storage within a fault tolerant repository. In short, this means that if any member of the array, that is, any one of the hard disk drives in the array suffers a complete failure, no data is lost: the drive failure has been "tolerated" (the RAID-5 becomes degraded to RAID-0). HP ProLiant Servers Troubleshooting Guide HP ProLiant Servers Troubleshooting Guide October 2003 (Second Edition) Part Number 338615-002 HP CONFIDENTIAL File Name: 338615-2.doc Last Saved On: 11/6/03 10:34 AM